• How to display OAT (Outside Air Temp) with MB SD C4

    Share my experience here! Yesterday, I have used <ahref="http: www.mbstartool.com="" wholesale="" mb-sd-connect-compact-4-star-diagnosis-cars-trucks.html"="">MB SD connect c4to display the outdoor air temperature on the status line of the bottominstrument clusterdisplay.

     

    I used:

    SD Connect C4 diagnostic tool

    Latest version 2016.03V Xentry

    Laptop with Win 8 operating system
    Steps to display the OAT:

    Change the National identity from GB to Nederlands(my choice) as GB cars are prevented from displaying the temperature on the statusline.
    In theBody Control Unit Menu
    selectRear Sam
    selectControl Unit Adaptations
    thenNational version of ATA function
    now choose a suitable National version
    and write change to Control Unit.
    In theInstrument ClusterMenu
    selectDiagnosis to plant specifications
    In theMain Menu of Control Module K16
    selectControl unit adaptations
    In theControl unit adaptations menu
    selectControl unit adaptations (Variant Coding)

    (if at this stage you select Menu-Werkseinstellung (Factory settings) and check the entry in Anzeige in Statuszeile you should find Geschwindigkeit if the car is UK registered. )

    selectAktuelle Menueinstellung
    change entries in
    Anzeige in Statuszeile
    toAussentemperatur (3 times)
    selectVariantenkodierung
    changeMenu 04 to Vorhanden
    enableMenu 05 and Menu 08

    save coding and retire with a stiff drink.

    Done!

    source:http://blog.mbstartool.com/2016/04/28/display-outside-air-temp-with-mb-sd-c4/